Platisil™ PH (New)

Platisil PH columns are well-suited for the separation of aromatic and polar compounds in RP mode. The retention characteristics are similar to those of the C8 phase, but with lower hydrophobicity. The presence of the phenyl functional group provides π-π interactions and offers alternative selectivity compared to traditional alkyl bonded phases, thereby expanding the range of selectivity options available. These columns provide sharp peaks and great reproducibility run-to-run, column-to-column, and batch-to-batch. The high coverage combined with a thorough endcapping makes Platisil PH columns more stable and durable.

 

Features of Platisil™ PH Columns

•  Monomerically bonded phenyl group
•  Alternative selectivity from π-π interactions
•  Exceptionally high surface coverage and superior stability
•  Lower hydrophobicity than C8 columns for rapid elution of hydrophobic analytes
•  Excellent resolution and reproducibility
•  Suitable for the separation of polar compounds, aromatic compounds, and isomers

 

Platisil™ PH Material Characteristics

Bonded phase

Particle size(μm)

Pore size(Å)

Surface area(m2/g)

Purity(%)

Phase density(µmol/m2)

Carbon loading(%)

pH range

Endcapping

 Phenyl

3, 5, 10

100

440

>99.999

4.1

14

1.5-7.5

Yes


 

 

Aniline homologs
Column: Listed on chromatograms   
Dimension: 150 × 4.6 mm, 5 µm  
Mobile Phase:

MeOH:H2O = 60:40

 
Flow Rate: 1.0 mL/min  
Detection: UV 254 nm  
Temperature: Ambient  
Sample: 1. Aniline                  5. N-Ethylaniline
  2. o-Toluidine  6. N,N-Dimethylaniline
  3. N-Methylaniline 7. N,N-Diethylaniline
  4. 2-Ethylaniline  

Dikma Platisil PH (Cat#: 99510)

GL Inertsil Ph-3

 

 

Polar acids (Enhanced selectivity)
Column: Listed on chromatograms    
Dimension: 150 × 4.6 mm, 5 µm  
Mobile Phase: MeCN+0.1%HCOOH:H2O+0.1%HCOOH = 30:70  
Flow Rate: 1.0 mL/min  
Detection: UV 254 nm  
Temperature: Ambient  
Sample: 1. p-Aminobenzoic acid                       3. Benzoic acid
  2. Sorbic acid                4. Salicylic acid

Dikma Platisil PH  (Cat#: 99510)

 

Dikma Inspire C18  (Cat#: 81001)

 

GL Inertsil Ph-3

 

 

Phenol homologs
Column: Listed on chromatograms    
Dimension: 150 × 4.6 mm, 5 µm  
Mobile Phase:

MeCN+0.1%HCOOH:H2O+0.1%HCOOH = 55:45

 
Flow Rate: 1.0 mL/min  
Detection: UV 280 nm  
Temperature: Ambient  
Sample: 1. Phenol 4. 2-Nitrophenol
  2. 4-Nitrophenol 5. 2, 4-Dichlorophenol
  3. 2-Chlorophenol 6. 2, 4, 6-Trichlorophenol

Dikma Platisil PH (Cat#: 99510)

GL Inertsil Ph-3

 

 

Steric selectivity
Column: Listed on chromatograms    
Dimension: 150 × 4.6 mm, 5 µm  
Mobile Phase:

MeOH:H2O = 75:25

 
Flow Rate: 1.0 mL/min  
Detection: UV 254 nm  
Temperature: Ambient  
Sample: 1. N,N-Dimethylaniline 4. trans-Stilbene
  2. Ethylbenzene 5. Bibenzyl
  3. Propylbenzene  

Dikma Platisil PH (Cat#: 99510)

GL Inertsil Ph-3